Class 12 · Alternating current
The transformer and the power line
Two coils on one iron core share the same changing flux, so their voltages are in the ratio of their turns. Stepping the voltage up brings the current down for the same power, and the heat wasted in a long line goes as the square of the current. That is why power travels at hundreds of kilovolts.
or open it full screen →
Free, in your browser, nothing to install. Topic: Transformers.
The textbook's answers
At the starting settings. As it runs, the simulation measures each of these and shows its value beside the textbook's.
| Voltage after the transformer, VₚNₛ/Nₚ (kV) | 40 |
|---|---|
| Current in the line, P/V (A) | 20 |
| Power lost in the line, I²R (kW) | 6 |
What you can change
Every slider changes the physics, not just the picture: the engine works it all out again.
| Setting | Range | Starts at |
|---|---|---|
| Turns of the secondary | 10 to 5,000 | 1,000 |
| Turns of the primary | 10 to 1,000 | 100 |
| Voltage of the generator | 200 to 20,000 V | 4,000 V |
| Power to be sent | 10 to 2,000 kW | 800 kW |
| Resistance of the line | 1 to 50 Ω | 15 Ω |